Principles of different types of solenoid valves

Installation method of magnetic pirated level gauge

  1. According to the medium condition, the solenoid valve can regularly open the drain flange to clean the sedimentation material of the main pipe.

  2. The installation of the magnetic pirated level gauge must be vertical to ensure that the float assembly can move up and down freely in the main tube.

  3. Do not allow a magnet to be near the main body of the magnetic pirated level gauge, otherwise it will directly affect the correct operation of the magnetic pirated level gauge.

    4. After the installation of the magnetic pirated level gauge is completed, the gas solenoid valve needs to be calibrated with magnetic steel to guide the turning column once to make the red below the zero position and white above the zero position.

  5. When the magnetic pirated level gauge is put into operation, you should first open the lower pipe valve to let the liquid medium enter the main pipe smoothly, so as to avoid the liquid medium from rising rapidly with the floating ball assembly, and causing the column turning failure and disorderly turning. If this happens, wait for the liquid level to stabilize and recalibrate with magnet.

       6. In order not to damage the float assembly during transportation, the float assembly is taken out of the main tube of the magnetic pirated level gauge before leaving the factory. After the magnetic pirated level gauge is installed, open the bottom drain flange, and then float it. Re-install the ball assembly into the main pipe. Note that the heavy end of the float assembly faces upwards. The high-temperature solenoid valve cannot be inverted. If the float assembly has been installed in the main tube at the factory, in order to ensure that the float assembly is not damaged during transportation, we fix the float assembly in the main tube with a soft card, and only need to pull out the soft card during installation.


This article is original by the manufacturer of the magnetic turning column level gauge, please indicate http://www.sungofluid.com/