What to pay attention to when buying a magnetic pirated level gauge

Magnetic pirated level gauges are widely used, so Yongjia Shangzheng Fluid Technology Co., Ltd., a manufacturer of magnetic pirated column level gauges, must list the details that some users must pay attention to when ordering magnetic pirated level gauges. For your reference.


  One aspect: you must first understand the occasion where your equipment is running and what the measuring medium is. Even if you don’t know what material you need, the manufacturer can determine the material used in the equipment according to the medium.


    The second aspect: When the electric actuator is equipped with a remote transmission supporting instrument, the following things need to be done:

  

   The remote transmission supporting instrument should be close to the main conduit of the level gauge and fixed with a stainless steel hoop (iron is prohibited);

  

  The sensing surface of the remote transmission supporting instrument should face and be close to the main conduit;

  

  The zero position of the remote transmission supporting instrument should be on the same horizontal line as the zero position indicator of the liquid level gauge;

  

  The connection between the remote transmission supporting instrument and the display instrument or industrial computer is well laid alone through a protective tube or laid with a shielded two-core cable;

  

   After the wiring hole of the junction box is installed, it must be well sealed to prevent rain, moisture, etc. from intruding and causing the remote transmission instrument to fail to work properly. The junction box should be covered in time after the completion of maintenance or debugging.

  

   The third aspect, the gas solenoid valve should be cleaned from time to time to remove impurities according to the medium condition;

  

   The fourth aspect, for level gauges that exceed a certain length (normal type> 3 meters, anti-corrosion type> 2 meters):

  

  Need to add a middle reinforced flange or ear pan as a fixed support to increase the strength and overcome its own weight;

  

   The fifth aspect, the installation position of the magnetic pirated level gauge:

  

   should avoid or stay away from the inlet and outlet of the material medium to avoid the rapid change of the material fluid in the local area, which will affect the accuracy of liquid level measurement;

  

   The sixth aspect, when debugging the magnetic pirated level gauge:

  

Open the upper valve of the lead pipe first, and then slowly open the lower valve of the solenoid valve to allow the medium to enter the main duct smoothly (the medium should be prevented from impacting the float rapidly during operation, causing the float to fluctuate and affecting the display accuracy), and observe whether the magnetic red and white ball is turned over If it is normal, then close the lower lead valve, open the drain valve, and let the liquid level in the main pipe drop. According to this method, operate three times, it is normal, and it can be put into operation (except for special liquids such as corrosive);


    Magnetic pirated level gauges also have other names on the market, but the parameters that need to be known for ordering are certain, such as corrosive media that need anti-corrosion materials, and the level of corrosion protection varies by the same amount according to the corrosive level of the media. We need to choose the right product according to our actual situation.